33 Results for the search " AC":
Protection Systems Against Lightning-Originated Overvoltages in Resonant Grounded Power Distribution Systems
Description:
A joint research project between AES Sul, the Federal University of Itajubá and the University of Bologna aims at defining the required protections against lightning-originated overvoltages in a reso... see morenant grounded distribution system in order to achieve the adequate lightning performance level with minimum cost. The paper aims at illustrating the effectiveness of the presence of a surge arrester or spark gap and their protective zone by means of simulations obtained with a computer code for the calculation of lightning induced voltages that takes also into account the steady-state voltage. The results of a statistical analysis for a single multiconductor line are eventually presented and discussed.
Authors: A. Borghetti, F. Napolitano, C.A. Nucci, M.L.B. Martinez, G.P. Lopes, J.I.L. Uchoa
2012 International Conference on Lightning Protection (ICLP), Vienna, Austria
Tag(s): Lightning protection, power distribution networks, induced overvoltages.
Continuous-Wavelet Transform for Fault Location in Distribution Power Networks: Definition of Mother Wavelets Inferred From Fault Originated Transients
Description:
The paper presents a fault location procedure for distribution networks based on the wavelet analysis of the fault-generated traveling waves. In particular, the proposed procedure implements the conti... see morenuous wavelet analysis applied to the voltage waveforms recorded during the fault in correspondence of a network bus. In order to improve the wavelet analysis, an algorithm is proposed to build specific mother wavelets inferred from the fault-originated transient waveforms. The performance of the proposed algorithm are analyzed for the case of the IEEE 34-bus test distribution network and compared with those achieved by using the more traditional Morlet mother wavelet.
Authors: Alberto Borghetti, Senior Member, IEEE, Mauro Bosetti, Mauro Di Silvestro, Carlo Alberto Nucci, Fellow, IEEE, and Mario Paolone, Member, IEEE
IEEE TRANSACTIONS ON POWER SYSTEMS, VOL. 23, NO. 2, MAY 2008
Tag(s): Continuous wavelet transform, distribution network, EMTP simulations, fault location, mother wavelet, power quality.
Co-simulation Platform for the Analysis of Communication-based
Description:
The paper presents an ICT and power co-simulation platform for the analysis of the volt/var control and relevant optimization in medium voltage distribution feeders, achieved by means of a system of d... see moreistributed controllers coordinated via a shared band-limited digital communication network. The platform has been built by realizing the interface between two specific simulation environments: the Electromagnetic Transient Program EMTP-RV and the communication network simulator Opnet Modeller. The preliminary results provide basic indications on the expected performances of the considered communication-based strategies for different traffic congestion levels and load/generation dynamic variations.
Tag(s): Co-simulation, Networked Control Systems, Power distribution feeders, Volt/var optimization
Control Devices of TACS
Description:
An EMTP-RV TACS (Transient Analysis Control Systems Library) containing :
- TACS 50 : Frequency meter
- TACS 51 : Relay
- TACS 52 : Level-Switch
- TACS 53 : Delay
- TACS 54 :... see more Pulse delay
- TACS 55 : Digitizer
- TACS 56 : X-Y point list
- TACS 57 : Sequenced switch
- TACS 58: Integrator
- TACS 59 : Derivator
- TACS 60 : Input Selector
- TACS 61 : Input Selector
- TACS 62 : Sample and Track
- TACS 63 : Instantaneous Max/Min
- TACS 64 : Max tracking
- TACS 65 : Accumulator
- TACS 66 : RMS Meter
Tag(s): TACS
A collection of PowerRelay devices
Description:
A collection of PowerRelay devices
Distance relay 21,
Synchronizing or synchronism-check device 25,
Instantaneous overcurrent 50 + Ac time overcurrent relay 51,
Frequency relay (ov... see moreer) 81O,
Frequency relay (rate) 81R,
Frequency relay (under) 81U
Plus 6 controlled switch build to connect with theses protection devices.
Tag(s): Protection