6 Results for the search " MAT":
Vary parameters, start simulation and export scope waveforms by script
Description:
This script is a simple example to learn how to script.
The script is started from the EMTP design by double clicking on the 'Script1' grey button.
The script example:
... see more
- varies a fault resistance
- runs a simulation for each value
- exports results of a selected list of scope in MAT and ASCII formats
- returns Min and Max
Tag(s): script, script, ASCII, MAT, parametric, minimum, maximum
Modular Multilevel Matrix Converter for Low-Frequency AC Transmission – modeling and Simulation in EMTP
Description:
Authors: Rafael Castillo-Sierra and Giri Venkataramanan
The transmission of power with AC faces limitations both to the stable operation of the electrical system and to the physical properties of... see more the transmission lines. Therefore, alternatives are being sought to mitigate these problems without the need to build new lines or replace existing ones with new, more powerful ones. In this context, a proven method makes it possible to overcome these problems by reducing the frequency at which power is transmitted. This method is known as Low Frequency AC Transmission (LFAC). In this sense, the model presented in this Research Contribution Prize Program EMTP® 2021 shows the implementation of a low-frequency transmission line in a small power system. The model presented shows a new block in EMTP of the AC/AC converter used, the Modular Multilevel Matrix Converter (MMMC) and the controls necessary for its operation. Time domain studies show that the technology is feasible and has the potential to improve the controllability and stability of transmission systems.
Tag(s): AC-AC power conversion, Electromagnetic Transient Studies in EMTP, Low frequency AC transmission, Modular Multilevel Matrix Converter
Power System with a Transmission Line operating at low frequency
Description:
Demonstration of the operation of a power system with a transmission line in low frequency. This model contains a 5-bus power system with a transmission line operated at a frequency of 41Hz.
The ... see moresystem includes:
- Model of frequency converters (averaged model of the Modular Multilevel Matrix Converter, MMMC).
- Converters control schemes.
- Initialization branches to include the low frequency line in the steady-state calculation.
- Internal variables of the converters such as voltages in the storage capacitors, branch currents, internal voltages, among others, can be plotted.
- External variables to the converters such as power flow in the low frequency line, currents and voltages can also be plotted.
Tag(s): MMMC, Low-Frequency AC Transmission, Power System Operation, Power converters, Control of power converters
DISPERSED ENERGY RESOURCES SCHEDULING FOR THE INTENTIONAL ISLANDING OPERATION OF DISTRIBUTION SYSTEMS
Description:
The paper presents an algorithm for the automatic optimal scheduling of dispersed energy resources (DERs) and of under-load tap changers (ULTCs) position. The aim of the scheduling problem consists in... see more the minimization of the voltage deviations with respect the rated value, of the DERs production deviation with respect the maximum efficiency point, and of the network losses.
The system incorporates also a procedure to facilitate the intentional islanding maneuver of the distribution network. The adopted approach is based on iterative solution of linear-constrained multi-objective optimization problems. The nonlinear power flow relationships are linearized by means of the calculation of sensitivity coefficients to small variations of the control variables (namely, controllable DERs power outputs and ULTCs positions). The algorithm is implemented in Matlab environment to exploit different solvers and suitably interfaced with EMTP-RV for three-phase power flow detailed calculations. In particular, two optimization solvers are adopted: the least square method and the goal attainment approach. The relevant results are compared using the IEEE 34-node distribution feeder as test case.
Authors: A. Borghetti, C.A. Nucci, M. Paolone, M. Bosetti
Tag(s): Dispersed generation, active distribution networks, islanding operation.
Parameters Identification of a Power Plant Model for the Simulation of Islanding Transients
Description:
The paper presents a procedure for parameter identification along with its application to the model of a combined cycle power plant that includes the surrounding electrical network, built for the anal... see moreysis of islanding maneuvers transients. The paper illustrates both the power system computer model, implemented within the EMTP-RV simulation environment, and the developed identification procedure based on the interface between the developed model and Matlab. The parameter identification procedure is applied to experimental transient recordings that make reference to a similar power plant.
Authors: A. Borghetti, C.A. Nucci, M. Paolone, M. Bosetti
Tag(s): Islanding, Identification, Power Plant