67 Results for the search "EV":
Author: h.gras
Type: Example
Downloaded: 240 times
Date: 2017-02-03
Tutorial on exported mask (Demonstrated with an exciter)
Description:
In this example, a device is placed in a subcircuit. The goal is to be able to modify the parameters of this device from the parent mask.
However, this device is a masked subcircuit and therefore... see more ## are not accepted. Here are two options to achieve this task.
Tag(s): exported, mask, exciter, governor, subcircuit, subnetwork, script, method
Author: n.sene
Type: Publication
Date: 2015-10-22
Fault Current Limiters in Industrial Power Systems
Description:
The concept of saturable core fault current limiter (FCL) is relatively known nowadays. It usually consists of two reversely magnetized cores per phase to effectively limit the fault current passively... see more and immediately upon its inception. In this paper prospects of application of fault current limiters in industrial power systems will be considered. Industrial power systems (distribution networks) are widespread and include a number of various electrical appliances. The power systems development (addition of new power plants, interconnections, etc.) may lead to more intense short circuit currents at the fault location. Furthermore, industrial systems may possess on-site generation which can increase fault current levels as well. All these factors might require appropriate upgrades of industrial system electrical equipment (especially switchgear) or special operating procedures (for instance avoiding parallel operation). Another alternative is the installation of fault current limiters. In this light, a series of simulations were carried out in order to observe the impact of fault current limiters on short circuit currents in an industrial power system using the EMTP-RV software program.
Keywords: saturable core fault current limiter (FCL), industrial power system, induction machine, EMTP; fault current analysis, medium voltage
Tag(s): saturable core fault current limiter (FCL), industrial power system, induction machine, EMTP; fault current analysis, medium voltage
Author: h.gras
Type: Example
Downloaded: 669 times
Date: 2015-06-16
Content of the webinar studies from A to Z on TRV
Description:
Designs built or presented during the webinar of the series Studies from A to Z on Transient Recovery Voltage
Models built:
- Rating TRV envelop (IEC 62271-100 / C37.010 - 2011)
- CP / ... see moreFD lines
- Thevenin equivalent of a network
Tag(s): TRV, Transient recovery voltage, short-line fault, terminal fault, substation, 62271, 37.011, lines, switching, thevenin
Author: n.sene
Type: Publication
Date: 2015-04-02
Short-Term Scheduling of Active Distribution Systems
Description:
The latest distribution management systems tend to incorporate optimization functions for the short-term scheduling of the various energy and control resources available in the network (e.g., embedded... see more generators, reactive power compensators and transformers equipped with on-load tap changers). The short-term scheduling procedure adopted in the paper is composed by two stages: a day-ahead scheduler for the optimization of distributed resources production during the following day, an intra-day scheduler that every 15 minutes adjusts the scheduling in order to take into account the operation requirements and constraints of the distribution network. The intra-day scheduler solves a non-linear multi-objective optimization problem by iteratively applying a mixed-integer linear programming (MILP) algorithm. The linearization of the optimization function and the constraints is achieved by the use of sensitivity coefficients obtained from the results of a three phase power flow calculation. The paper shows the application of the proposed approach to a medium-voltage 120 buses network with 10 dispatchable generators and 2 transformers equipped with on-load tap changers.
Authors: A. Borghetti, M. Bosetti, S. Grillo, M. Paolone, F. Silvestro
IEEE Bucharest Power Tech Conference, June 28th - July 2nd, Bucharest, Romania
Tag(s): Distributed generation, operation of distribution networks, MILP.
Author: n.sene
Type: Publication
Date: 2015-04-02
Indirect Lightning Performance of a Real Distribution Network with focus on Transformer Protection
Description:
The paper applies the Monte Carlo procedure proposed by the Authors to evaluate the indirect lightning performance of a real medium-voltage distribution network, which includes feeders and laterals, p... see moreoles, secondary substations and surge protection devices. Such a procedure allows inferring the amplitude of lightning-induced voltages at any point and any phase of the network. The analysis presented in this paper aims at assessing the expected mean time between failures of each MV/LV transformer caused by indirect lightning strikes.
A heuristic technique has been specifically developed to reduce the computational effort despite the non-linear response of the network enhanced by the presence of surge arresters.
Authors: Alberto Borghetti, Fabio Napolitano, Carlo Alberto Nucci, Fabio Tossani, Gilnei J. G. Dos Santos, Donorvan R. Fagundes, Gustavo P. Lopes, Manuel L. B. Martinez
2014 International Conference on Lightning Protection (ICLP), Shanghai, China
Tag(s): induced voltages; distribution networks; Monte Car lo method; lightning protection; MTBF.