Waveform Visualization and Post Processing
Error when starting MPLOT: The version of this file is not compatible with the version of Windows you are running?
• License type: any
• Occurrence: on MPLOT opening
When trying to open MPLOT, it does not open and instead the following message pops up:
• Solution
- Your computer is likely to run Windows on a 32-bit operating system. More inf
How to configure MPLOT for 32-bit operating systems?
- Go to the EMTPWorks installation folder C:Program FilesEMTPWorks 3.xEMTPTranslator, 3.X being the EMTP version number.
- Identify file mplot.exe and rename it as mplot64.exe.
- Identify file mplotold.exe and rename it as mplot.exe.
- Try to open MPLO
How to perform an FFT on a signal window
1. In ScopeView, open Advanced
function editor.
2. In the window, choose Miscellaneous and Limit:
Select the signal, and the left and right boundaries.
3. &nb
How to reduce waveform datafile size
By default, all simulated time-steps are
displayed by ScopeView or Mplot. When a simulation is performed with a very
large number of time-steps, waveforms are saved in extremely large binary files
and visualization tools such as ScopeView may not b
ScopeView Error: Error during data acquisition. Java heap space
By default, all simulated time-steps are
displayed by ScopeView or Mplot. When a simulation is performed with a very
large number of time-steps, waveforms are saved in extremely large binary files
and visualization tools such as ScopeView may not