Content of the webinar studies from A to Z on TRV
Description:
Designs built or presented during the webinar of the series Studies from A to Z on Transient Recovery Voltage
Models built:
- Rating TRV envelop (IEC 62271-100 / C37.010 - 2011)
- CP / ... see moreFD lines
- Thevenin equivalent of a network
Tag(s): TRV, Transient recovery voltage, short-line fault, terminal fault, substation, 62271, 37.011, lines, switching, thevenin
Content of the webinar studies from A to Z on lightning strokes
Description:
Designs built or presented during the webinar of the series Studies from A to Z on Lightning stroke analysis.
Models built:
- Metal Oxide surge arrester (IEEE working group 3.4.11)
- To... see morewer model for fast-front transients.
- Footing resistance of towers (with ionization effect)
- air-gap leader (Area Criterion Model and equal area integration (Cigre))
- FD lines
- Substation equipment
- Parametric studies
- Corona
Tag(s): Lightning, stroke, fast-front transient, tower, arrester, cigre, line, substation, parametric, corona, air-gap, leader
Short-Term Scheduling of Active Distribution Systems
Description:
The latest distribution management systems tend to incorporate optimization functions for the short-term scheduling of the various energy and control resources available in the network (e.g., embedded... see more generators, reactive power compensators and transformers equipped with on-load tap changers). The short-term scheduling procedure adopted in the paper is composed by two stages: a day-ahead scheduler for the optimization of distributed resources production during the following day, an intra-day scheduler that every 15 minutes adjusts the scheduling in order to take into account the operation requirements and constraints of the distribution network. The intra-day scheduler solves a non-linear multi-objective optimization problem by iteratively applying a mixed-integer linear programming (MILP) algorithm. The linearization of the optimization function and the constraints is achieved by the use of sensitivity coefficients obtained from the results of a three phase power flow calculation. The paper shows the application of the proposed approach to a medium-voltage 120 buses network with 10 dispatchable generators and 2 transformers equipped with on-load tap changers.
Authors: A. Borghetti, M. Bosetti, S. Grillo, M. Paolone, F. Silvestro
IEEE Bucharest Power Tech Conference, June 28th - July 2nd, Bucharest, Romania
Tag(s): Distributed generation, operation of distribution networks, MILP.
Indirect Lightning Performance of a Real Distribution Network with focus on Transformer Protection
Description:
The paper applies the Monte Carlo procedure proposed by the Authors to evaluate the indirect lightning performance of a real medium-voltage distribution network, which includes feeders and laterals, p... see moreoles, secondary substations and surge protection devices. Such a procedure allows inferring the amplitude of lightning-induced voltages at any point and any phase of the network. The analysis presented in this paper aims at assessing the expected mean time between failures of each MV/LV transformer caused by indirect lightning strikes.
A heuristic technique has been specifically developed to reduce the computational effort despite the non-linear response of the network enhanced by the presence of surge arresters.
Authors: Alberto Borghetti, Fabio Napolitano, Carlo Alberto Nucci, Fabio Tossani, Gilnei J. G. Dos Santos, Donorvan R. Fagundes, Gustavo P. Lopes, Manuel L. B. Martinez
2014 International Conference on Lightning Protection (ICLP), Shanghai, China
Tag(s): induced voltages; distribution networks; Monte Car lo method; lightning protection; MTBF.
Selection of MV/LV Transformers to be Protected by Surge Arresters against Indirect Lightning Overvoltages
Description:
The papers addresses the problem of locating surge protective devices in a medium voltage distribution network by means of an accurate computer model for the calculation of lightning induced overvolta... see moreges and a Monte Carlo statistical procedure. The indirect lightning performance of small network cells of different configuration are evaluated and used as a benchmark for the validation of the surge arrester locations provided by a genetic algorithm procedure. The obtained results appear useful for the lightning protection design of networks
with complex topology.
Authors: Alberto Borghetti, Fabio Napolitano, Carlo Alberto Nucci, Fabio Tossani, Gilnei J. G. Dos Santos, Donorvan R. Fagundes, Gustavo P. Lopes, Manuel L. B. Martinez
2014 International Conference on Lightning Protection (ICLP), Shanghai, China
Tag(s): distribution network; surge arresters; lightning protection.