35 Results for the search "line":
INDUCED VOLTAGES AND CURRENTS: OVERVIEW AND EVALUATION OF SIMULATION MODELS AND METHODOLOGIES
Description:
In this paper induced voltages and currents caused by underground cables are calculated in cable sheaths and nearby metallic pipelines. The performance of several simulation methods and models are inv... see moreestigated in steady-state, considering also different implementations in ATP-EMTP, EMTP-RV and PSCAD/EMTDC. The analysis is extended in the simulation of transient overvoltages in cable systems, evaluating the accuracy of two widely used simulation models. The influence of different parameters is investigated, among them specifically the earth properties. Results reveal that implementing accurate earth representations, earth conduction effects have a significant impact on induced voltages at the power frequency, while for high frequency phenomena the influence is minor.
Tag(s): induced voltages
Fault on a line
Description:
This model is a faulty line. The distance of the fault from the origin is a parameter. CP or PI models are used on each side of the fault according to the time step. If the time step is small enough t... see moreo simulate the propagation in the line with at least 10 time steps, CP is used, else it is PI.
Content of the webinar studies from A to Z on TRV
Description:
Designs built or presented during the webinar of the series Studies from A to Z on Transient Recovery Voltage
Models built:
- Rating TRV envelop (IEC 62271-100 / C37.010 - 2011)
- CP / ... see moreFD lines
- Thevenin equivalent of a network
Tag(s): TRV, Transient recovery voltage, short-line fault, terminal fault, substation, 62271, 37.011, lines, switching, thevenin
Content of the webinar studies from A to Z on lightning strokes
Description:
Designs built or presented during the webinar of the series Studies from A to Z on Lightning stroke analysis.
Models built:
- Metal Oxide surge arrester (IEEE working group 3.4.11)
- To... see morewer model for fast-front transients.
- Footing resistance of towers (with ionization effect)
- air-gap leader (Area Criterion Model and equal area integration (Cigre))
- FD lines
- Substation equipment
- Parametric studies
- Corona
Tag(s): Lightning, stroke, fast-front transient, tower, arrester, cigre, line, substation, parametric, corona, air-gap, leader
Short-Term Scheduling of Active Distribution Systems
Description:
The latest distribution management systems tend to incorporate optimization functions for the short-term scheduling of the various energy and control resources available in the network (e.g., embedded... see more generators, reactive power compensators and transformers equipped with on-load tap changers). The short-term scheduling procedure adopted in the paper is composed by two stages: a day-ahead scheduler for the optimization of distributed resources production during the following day, an intra-day scheduler that every 15 minutes adjusts the scheduling in order to take into account the operation requirements and constraints of the distribution network. The intra-day scheduler solves a non-linear multi-objective optimization problem by iteratively applying a mixed-integer linear programming (MILP) algorithm. The linearization of the optimization function and the constraints is achieved by the use of sensitivity coefficients obtained from the results of a three phase power flow calculation. The paper shows the application of the proposed approach to a medium-voltage 120 buses network with 10 dispatchable generators and 2 transformers equipped with on-load tap changers.
Authors: A. Borghetti, M. Bosetti, S. Grillo, M. Paolone, F. Silvestro
IEEE Bucharest Power Tech Conference, June 28th - July 2nd, Bucharest, Romania
Tag(s): Distributed generation, operation of distribution networks, MILP.