2 Results for the search "thpapad":
MIMO-OFDM Narrowband-PLC in Distribution Systems: Impact of Power Transformers on Achievable Data Rates
Description:
Power-line communication (PLC) is gaining a renewed interest, due to the smart grid (SG) emerging communication requirements. Among other communication technologies, PLC is a very efficient and feasib... see morele solution, especially for the extended SG distribution networks. However, it is very challenging to consider both the medium- and low-voltage parts of the distribution network as a whole communication medium, due to the attenuating effects of distribution transformers, limiting PLC applicability. In this paper, data transmission through distribution transformers is investigated by means of multiple-input multiple-output (MIMO) narrowband power-line communication (NB-PLC) system, utilizing orthogonal frequency-division multiplexing (OFDM) technology. Multi-conductor distribution line and measurement-based transformer models are developed to characterize the MV-LV PLC channel. In addition, OFDM signal processing techniques are applied to enhance the achievable data rates. The transmit power budget and bit allocation across the OFDM sub-channels of the spatial beams are optimized to maximize the data rate through the distribution transformer. The achievable data rates are calculated and systematically analysed for different scenarios to investigate the effects of the distribution lines, connected loads, noise models, etc. Results reveal the superiority of the proposed MIMO design against the traditional SISO systems. In addition, the possibility for an extensive and reliable application of MV-LV PLC communications through distribution transformers is shown.
Tag(s): Distribution lines, distribution transformers, MIMO-OFDM, power-line communication, smart grids
INDUCED VOLTAGES AND CURRENTS: OVERVIEW AND EVALUATION OF SIMULATION MODELS AND METHODOLOGIES
Description:
In this paper induced voltages and currents caused by underground cables are calculated in cable sheaths and nearby metallic pipelines. The performance of several simulation methods and models are inv... see moreestigated in steady-state, considering also different implementations in ATP-EMTP, EMTP-RV and PSCAD/EMTDC. The analysis is extended in the simulation of transient overvoltages in cable systems, evaluating the accuracy of two widely used simulation models. The influence of different parameters is investigated, among them specifically the earth properties. Results reveal that implementing accurate earth representations, earth conduction effects have a significant impact on induced voltages at the power frequency, while for high frequency phenomena the influence is minor.
Tag(s): induced voltages