Technical Presentations

Access to EMTP user presentations, webinars, and slide deck presentations.

page 1 of 12

58 presentations for line:


Application of single phase tripping and re-closing to 380KV double circuit transmission line

Author(s): Jegadeesh Kumar
Type:Technical Presentation
Date: 2024-07-29

Rating:
* 0 vote(s)

Application of single phase tripping and re-closing to 380KV double circuit transmission line


Abstract
Faults within a transmission system can greatly impact the capability for power transfer. Isolating a fault by removing the line from service can further diminish the power transfer capacity, compromi... see more

Tag(s): Fault Analysis, Transmission System, Secondary Arc Current, Circuit Breaker

Dynamic EMT Models Homologation - Usage and Projection

Author(s): Lorena Otalora Garcia, Samantha Munoz
Type:Technical Presentation
Downloaded: 0
Date: 2024-07-29

Rating:
* 0 vote(s)

Dynamic EMT Models Homologation - Usage and Projection


Abstract
Since 2022, the National Electric Coordinator in Chile has requested standardization of the dynamic models of the power plants or parks connected to the National Electrical System (SEN). As a company ... see more

Tag(s): Wind Power Photovoltaic Systems, EMT Homologations, Chilean National Electrical System

Wide-area EMT simulation of Colombian Power system with high inverter-based-resources penetration and weak SCR network

Author(s): Ernesto Perez Gonzalez
Type:Technical Presentation
Downloaded: 0
Date: 2024-07-29

Rating:
* 0 vote(s)

Wide-area EMT simulation of Colombian Power system with high inverter-based-resources penetration and weak SCR network


Abstract
This presentation will focus on a specific issue of bipolar HVDC lines with a dedicated metallic return (DMR). DMR is insulated to a lower level than the pole and its insulators are shorter. One event... see more

Tag(s): Colombian Power System, EMT Model, Solar Power, Wind Power

FFOV Analysis for 500 kV Substation

Author(s): Melih Guneri
Type:Technical Presentation
Downloaded: 0
Date: 2024-07-29

Rating:
* 0 vote(s)

FFOV Analysis for 500 kV Substation


Abstract
This is a presentation on lightning overvoltage analyses for a 500/220 kV substation. Highlights: An interesting application case where the electrical distance between the surge arrester and transform... see more

Tag(s): Lightning Overvoltage Analysis, Surge Arrester

Sustained Overvoltage due to Zero Sequence Resonance for Shunt Compensated Transmission Lines

Author(s): Muhammad Humayan
Type:Technical Presentation
Downloaded: 0
Date: 2024-07-26

Rating:
* 0 vote(s)

Sustained Overvoltage due to Zero Sequence Resonance for Shunt Compensated Transmission Lines


Abstract
Shunt compensation reactors, deployed in long AC transmission lines, serve to mitigate overvoltages induced by capacitive charging under light load conditions. However, these reactors can introduce op... see more

Tag(s): Shunt Compensation, Zero Sequence Resonance, Overvoltages, Protection