Technical Presentations

Access to EMTP user presentations, webinars, and slide deck presentations.

page 3 of 4

20 presentations for inverter:


Optimization of Control Parameters of Grid-Connected PV System in EMTP

Author(s): Bikrant Poudel
Type:Technical Presentation
Date: 2021-09-02

Rating:
* 0 vote(s)

Optimization of Control Parameters of Grid-Connected PV System in EMTP


Abstract
It is observed that the controller gain parameters of the PV model have a significant impact on the PV plant’s response during the fault recovery and the PV plant’s interaction with the rest of th... see more

Tag(s): pv plant, ibr, pso, optimization, scripting, pll, inverter control, inverter based resources, DER

Dynamic Overvoltage Conditions Experienced at a PV Solar Power Plant

Author(s): Chandra Pallem
Type:Technical Presentation
Date: 2021-09-02

Rating:
* 0 vote(s)

Dynamic Overvoltage Conditions Experienced at a PV Solar Power Plant


Abstract
We present the results from an investigation of the cause of dynamic overvoltage conditions experienced at a solar power plant, that resulted from energizing the PV solar plant 34.5 kV collection syst... see more

Tag(s): pv park, tov, diesel generator, temporary overvoltage

Ground Fault Overvoltage with Inverter-Based Distributed Energy Resources

Author(s): Aboutaleb Haddadi
Type:Technical Presentation
Date: 2021-09-02

Rating:
* 0 vote(s)

Ground Fault Overvoltage with Inverter-Based Distributed Energy Resources


Abstract
A Ground Fault Overvoltage (GFO) can occur in situations where an ungrounded transmission line and associated ungrounded transmission equipment is energized from distribution connected Distributed En... see more

Tag(s): gfov, tov, ibr, DER, inverter, islanding, load rejection, inverter based resources

TOV for renewable, evaluating three different grounding technologies

Author(s): Diego F. Rodríguez - GERS
Type:Technical Presentation
Date: 2021-06-17

Rating:
* 1 vote(s)

TOV for renewable, evaluating three different grounding technologies


Abstract
Temporary overvoltages (TOV) are oscillatory overvoltages mainly caused by switching or faults, which are of relatively long duration and undamped or slightly damped. Maximum overvoltages under faulte... see more

Use of EMTP in Transmission Planning Research

Author(s): Bob Arritt
Type:Technical Presentation
Date: 2021-03-05

Rating:
* 0 vote(s)

Use of EMTP in Transmission Planning Research


Abstract
The initiation of inverter-based generation (IBG), has been changing the characteristics of the grid. The addition of non-traditional generation sources gives rise to several grid concerns, such as re... see more

Most Watched Presentations