56 presentations for DER:


Optimization of Control Parameters of Grid-Connected PV System in EMTP

Author(s): Bikrant Poudel
Type:Technical Presentation
Date: 2021-09-02

Rating:
* 0 vote(s)

Optimization of Control Parameters of Grid-Connected PV System in EMTP


Abstract
It is observed that the controller gain parameters of the PV model have a significant impact on the PV plant’s response during the fault recovery and the PV plant’s interaction with the rest of th... see more

Tag(s): pv plant, ibr, pso, optimization, scripting, pll, inverter control, inverter based resources, DER

Dynamic Overvoltage Conditions Experienced at a PV Solar Power Plant

Author(s): Chandra Pallem
Type:Technical Presentation
Date: 2021-09-02

Rating:
* 0 vote(s)

Dynamic Overvoltage Conditions Experienced at a PV Solar Power Plant


Abstract
We present the results from an investigation of the cause of dynamic overvoltage conditions experienced at a solar power plant, that resulted from energizing the PV solar plant 34.5 kV collection syst... see more

Tag(s): pv park, tov, diesel generator, temporary overvoltage

Ground Fault Overvoltage with Inverter-Based Distributed Energy Resources

Author(s): Aboutaleb Haddadi
Type:Technical Presentation
Date: 2021-09-02

Rating:
* 0 vote(s)

Ground Fault Overvoltage with Inverter-Based Distributed Energy Resources


Abstract
A Ground Fault Overvoltage (GFO) can occur in situations where an ungrounded transmission line and associated ungrounded transmission equipment is energized from distribution connected Distributed En... see more

Tag(s): gfov, tov, ibr, DER, inverter, islanding, load rejection, inverter based resources

Measurement and EMTP Simulation of Ferroresonance Phenomenon

Author(s): Ivo Uglesic
Type:Technical Presentation
Date: 2021-09-02

Rating:
* 0 vote(s)

Measurement and EMTP Simulation of Ferroresonance Phenomenon


Abstract
Ferroresonance is difficult to predict because its occurrence in the power system depends on several parameters, some of which are unknown (parasitic capacities). In addition, measuring electrical con... see more

Tag(s): ferroresonance, tov, saturation

Real Case of a Resonance in a Power Plant

Author(s): Andreia Leiria
Type:Technical Presentation
Date: 2021-09-02

Rating:
* 0 vote(s)

Real Case of a Resonance in a Power Plant


Abstract
Overvoltages were identified on the MV and LV networks of a Hydro Power Plant as the cause of the trip of the LV maximum voltage protection, compromising the normal operation of the system. Following ... see more

Tag(s): harmonics, power uality, resonance

Most Watched Presentations

X