Technical Presentations

Access to EMTP user presentations, webinars, and slide deck presentations.

page 1 of 2

8 presentations for Circuit Breaker:


Application of single phase tripping and re-closing to 380KV double circuit transmission line

Author(s): Jegadeesh Kumar
Type:Technical Presentation
Date: 2024-07-29

Rating:
* 0 vote(s)

Application of single phase tripping and re-closing to 380KV double circuit transmission line


Abstract
Faults within a transmission system can greatly impact the capability for power transfer. Isolating a fault by removing the line from service can further diminish the power transfer capacity, compromi... see more

Tag(s): Fault Analysis, Transmission System, Secondary Arc Current, Circuit Breaker

Implementation of an Opening Resistor to Mitigate TRV in a Hydroelectric Project in the Peruvian Electrical System

Author(s): Marlon Lujan
Type:Technical Presentation
Downloaded: 0
Date: 2024-07-29

Rating:
* 0 vote(s)

Implementation of an Opening Resistor to Mitigate TRV in a Hydroelectric Project in the Peruvian Electrical System


Abstract
In this hydroelectric generation project, connection is established in a 500 kV system, which includes series compensation. A comprehensive TRV analysis was conducted to evaluate the existing circuit ... see more

Tag(s): Hydroelectric Generation, Series Compensation, Circuit Breakers, TRV Analysis

Sustained Overvoltage due to Zero Sequence Resonance for Shunt Compensated Transmission Lines

Author(s): Muhammad Humayan
Type:Technical Presentation
Downloaded: 0
Date: 2024-07-26

Rating:
* 0 vote(s)

Sustained Overvoltage due to Zero Sequence Resonance for Shunt Compensated Transmission Lines


Abstract
Shunt compensation reactors, deployed in long AC transmission lines, serve to mitigate overvoltages induced by capacitive charging under light load conditions. However, these reactors can introduce op... see more

Tag(s): Shunt Compensation, Zero Sequence Resonance, Overvoltages, Protection

Analysis of transient recovery voltage on circuit-breaker connected to HV terminals of step-up transformer located in hydro power plant

Author(s): Bozidar Filipovic,Nina Stipetic, Franjo Vukovic
Type:PDF Presentation
Downloaded: 5
Date: 2022-09-01

Rating:
* 0 vote(s)

Analysis of transient recovery voltage on circuit-breaker connected to HV terminals of step-up transformer located in hydro power plant


Abstract
This presentation deals with TRV on circuit-breaker installed in GIS at HV terminals of step-up transformer located in hydro power plant. An overview of standards covering TRV will be given. Modelling... see more

Tag(s): Transient Recovery Voltage (TRV), Step-Up Transformer, Generator Synchronization, Out-of-Phase Switching, Short-Circuit

Analysis and Calculations in Medium Voltage Electrical Systems

Author(s): Stefano Vitali
Type:Technical Presentation
Date: 2021-09-06

Rating:
* 1 vote(s)

Analysis and Calculations in Medium Voltage Electrical Systems


Abstract
The electrical installation of an industrial site is a complex structure. Analyzing behavior in a transient condition allows optimum selection of the operation and protection devices in the installati... see more

Tag(s): TRV, generator breaker, filter, switching