See Transient recovery voltages in vacuum circuit breakers generated by the early-interruption of the inrush current of large motors

Author: n.sene
Type: Publication
Date: 2015-04-01

Rating:
* 0 vote(s)

Transient recovery voltages in vacuum circuit breakers generated by the early-interruption of the inrush current of large motors

Description:
The switching of medium voltage electrical motors is typically realized by means of vacuum circuit breakers (VCBs) essentially in view of their elevated number of switching cycles. As known, switching... see more


Tag(s): Transient recovery voltages, vacuum circuit breakers, motor inrush currents, EMTP simulations

See Continuous-Wavelet Transform for Fault Location in Distribution Power Networks: Definition of Mother Wavelets Inferred From Fault Originated Transients

Author: n.sene
Type: Publication
Date: 2015-04-01

Rating:
* 0 vote(s)

Continuous-Wavelet Transform for Fault Location in Distribution Power Networks: Definition of Mother Wavelets Inferred From Fault Originated Transients

Description:
The paper presents a fault location procedure for distribution networks based on the wavelet analysis of the fault-generated traveling waves. In particular, the proposed procedure implements the conti... see more


Tag(s): Continuous wavelet transform, distribution network, EMTP simulations, fault location, mother wavelet, power quality.

See Javascript : Add C devices + change values + connect devices (EMTP 3.0)

Author: ali.el-akoum
Type: Example
Downloaded: 396 times
Date: 2014-11-14

Rating:
* 0 vote(s)

Javascript : Add C devices + change values + connect devices (EMTP 3.0)

Description:
Javascript : Add C devices + change values + connect devices (EMTP 3.0)

Example for EMTP 3.0


Tag(s): Javascript, Add devices, change values, connect devices

See Javascript : Add C devices + change values + connect devices

Author: ali.el-akoum
Type: Example
Downloaded: 276 times
Date: 2014-09-17

Rating:
* 1 vote(s)

Javascript : Add C devices + change values + connect devices

Description:
Javascript :
* Add C devices
* Change values
* Connect devices

(for EMTP-RV 2.5)


Tag(s): Javascript, Add devices, change values, connect devices

See Co-simulation Platform for the Analysis of Communication-based

Author: admin2012
Type: Document
Downloaded: 183 times
Date: 2014-06-02

Rating:
* 0 vote(s)

Co-simulation Platform for the Analysis of Communication-based

Description:
The paper presents an ICT and power co-simulation platform for the analysis of the volt/var control and relevant optimization in medium voltage distribution feeders, achieved by means of a system of d... see more


Tag(s): Co-simulation, Networked Control Systems, Power distribution feeders, Volt/var optimization