35 Results for the search "line":
line modification by script (CP multiphase)
Description:
This function changes lenght of CP-multiphase line called "lineName" to the desired length.
Tag(s): CP line, script, length, multiphase
Power System with a Transmission Line operating at low frequency
Description:
Demonstration of the operation of a power system with a transmission line in low frequency. This model contains a 5-bus power system with a transmission line operated at a frequency of 41Hz.
The ... see moresystem includes:
- Model of frequency converters (averaged model of the Modular Multilevel Matrix Converter, MMMC).
- Converters control schemes.
- Initialization branches to include the low frequency line in the steady-state calculation.
- Internal variables of the converters such as voltages in the storage capacitors, branch currents, internal voltages, among others, can be plotted.
- External variables to the converters such as power flow in the low frequency line, currents and voltages can also be plotted.
Tag(s): MMMC, Low-Frequency AC Transmission, Power System Operation, Power converters, Control of power converters
Active Harmonic Filter
Description:
The shunt filter injects the current that is defined as the error between the (non-linear) load current and the fundamental harmonic. The filter uses a 3-level inverter and the 2-level hysteresis curr... see moreent control.
Tag(s): filter, AHF, active filter
Overhead line field analysis
Description:
This example shows how to use EMTP and line data function to compute the magnetic and electric field in a vicinity of an overhead power line.
Tag(s): line, electric field, magnetic field
MIMO-OFDM Narrowband-PLC in Distribution Systems: Impact of Power Transformers on Achievable Data Rates
Description:
Power-line communication (PLC) is gaining a renewed interest, due to the smart grid (SG) emerging communication requirements. Among other communication technologies, PLC is a very efficient and feasib... see morele solution, especially for the extended SG distribution networks. However, it is very challenging to consider both the medium- and low-voltage parts of the distribution network as a whole communication medium, due to the attenuating effects of distribution transformers, limiting PLC applicability. In this paper, data transmission through distribution transformers is investigated by means of multiple-input multiple-output (MIMO) narrowband power-line communication (NB-PLC) system, utilizing orthogonal frequency-division multiplexing (OFDM) technology. Multi-conductor distribution line and measurement-based transformer models are developed to characterize the MV-LV PLC channel. In addition, OFDM signal processing techniques are applied to enhance the achievable data rates. The transmit power budget and bit allocation across the OFDM sub-channels of the spatial beams are optimized to maximize the data rate through the distribution transformer. The achievable data rates are calculated and systematically analysed for different scenarios to investigate the effects of the distribution lines, connected loads, noise models, etc. Results reveal the superiority of the proposed MIMO design against the traditional SISO systems. In addition, the possibility for an extensive and reliable application of MV-LV PLC communications through distribution transformers is shown.
Tag(s): Distribution lines, distribution transformers, MIMO-OFDM, power-line communication, smart grids